Posted on Leave a comment

Shineway OTDR – MTP-1000 OTDR

Shineway MTS-1000 OTDR
Shineway MTS-1000 OTDR
Shineway MTS-1000 OTDR

MTP-1000 OTDR Multifunctional Test Platform

Shineway OTDR MTP-1000 OTDR is a compact modular platform with up to 3 functional modules, which is specially designed for FTTx/PON applications and can meet all test requirements of installers, contractors and service operators during network installation, service activation, maintenance and troubleshooting.

Shineway OTDR MTP-1000 OTDR – Designed for Metro, Access & FTTx Networks

  • Shineway OTDR MTP-1000 OTDR – All-in-one: OTDR, VFL, PON Power Meter, Optical Power Meter, Stabilized Laser Source, Optical Connector Inspector
  • OTDR modules of flexible configurations for comprehensive applications:
    • LAN/WAN/FTTx
    • Double/triple/quad wavelength, SM/MM
    • Fault locating, fiber length/loss measurement, connector/ splice/ splitter/ macro bend/fiber-end detection
  • Pass-through PON Power Meter simultaneously measures Triple-play PON signals (1310/1490/1550nm)
  • Visible Fault Locator fast locates defective connectors, faults in macrobends, patch cords and patch cord panels
  • Remote/local control by PC
  • Optical Connector Inspector checks connector & fiber termination for polish quality & cleanliness

Shineway OTDR MTP-1000 OTDR- Optimized Platform Performance

  • Lightweight
  • 8.4 inch touch screen
  • Excellent Man-Machine interface for easy operation
  • Damp-dust-shock proof
  • Knob and stylus combination: Fast and easy handling
  • Optimized power management: 7 hours continuous operation
  • Fast power up with Windows CE
  • Direct printing (compatible with PCL printers)

OTDR Module

  • Multiple modules available for flexible configuration
  • LAN/WAN/FTTx application
  • GR-196-CORE (.SOR) file format
  • JPG file format
  • PON OTDR test through splitter, splitter & fiber-end identifiable
  • Multi-wavelength test
  • Auto/Manual test
  • File Naming Template

 Shineway MTS-1000 – General Loss Tester Module

  • Simultaneous Triple-play PON signals measurement (1310/1490/1550nm)
  • Burst mode 1310nm upstream signal detection & measurement
  • Dual-port pass-through design
  • 1310/1490/1550/1625nm Quad-wavelength Stabilized Laser Source
  • 850/1300/1310/1490/1550/1625/1650nm CAL wavelength Optical Power Meter
  • Automatic wavelength identification

Shineway OTDR MTP-1000 OTDR – Optical Connector Inspector Module

  • Focusing knob for fast focus
  • Eye-safe and clear video viewing
  • Interchangeable connector tips

Shineway OTDR MTP-1000 OTDR- MTPSuite Software

  • Multi traces comparison
  • Single/multi trace printing
  • Batch editing and printing
  • Bidirectional testing
  • CSV/ASCII report formats

Shineway OTDR MTP-1000 OTDR – Specifications

Platform
Display

8.4 inch TFT Touch Screen (800×600)

Connectivity

USB×2; 10/100Mbit/s RJ-45×1

Memory

2GB

Power Supply

Li-Ion Battery/AC Adapter

Battery Life

7 hours continuous operation

Weight

2.1kg (Platform only)

Dimensions (H×W×T)

320×190×70mm (Platform only)

OTDR Module

Wavelength (±20nm)

Dynamic Range (dB)

 EDZ(m)

    ADZ(m)

MOT200-20VD

1310/1550

45/43

1

7

MOT200-30VC

1310/1490/1550

38/37/37

1.5

12

MOT200-31VC

1310/1550/1625

38/37/37

1.4

9

MOT200-32VC

1310/1383/1550

38/37/37

1.5

12

MOT200-33VC

1310/1550/1650

38/37/37

1

    5/5/7

MOT200-40VC

850/1300/1310/1550

22/30/38/36

1.5

  8/8/10/10

MOT200-41VC

1310/1490/1550/1625

38/37/36/36

1.5

12

Selectable Range

SM: 1.3, 2.5, 5, 10, 20, 40, 80, 160, 240Km

MM: 1.3, 2.5, 5, 10, 20, 40Km

Pulse Width

SM: 5ns,10ns,30ns,100ns,300ns,1µs,2.5µs,10µs,20µs

MM: 5ns, 10ns, 30ns, 1µs, 2.5µs

Averaging Time

Quick, 15s, 30s, 45s, 60s, 90s, 120s, 180s

Emitter Type

LD

Connector

FC/PC (Interchangeable SC, ST)

Distance Measure Accuracy

±(1m + 10-5×distance + sampling space)

Attenuation Detect Accuracy

±0.05 dB/dB

Reflection Detect Accuracy

±4 dB

Visible Laser Source

     Output Power ≥ -3dBm; MOD Frequency: 1Hz; Detecting Range: 5Km
MPN100 Built-in OPM for OTDR Modules

CAL Wavelength

850,1300,1310,1490,1550,1625, 1650nm

Power Range (dBm)

-70~+10 (-60~+10@850nm)

MCI100 Optical Connector Inspector Module
Field of View

400µm×300µm

Resolution

≤1.5µm

Focusing

Manual Focus

Hand Probe Dimensions

Ø32×175mm

MPN200 General Loss Tester Module: PON Power Meter
CAL Wavelengths

1310

1490

1550

Measurement Range

-40 ~ +10dBm (1)

-40 ~ +12dBm

-40 ~ +20dBm

Spectral Passband

1310±50nm

1490±15nm

1550±10nm

Power Uncertainty

≤ 0.5dB

Display Resolution

0.01dB

Insertion Loss

≤ 1.5dB

MPN200 General Loss Tester Module: Stabilized Laser Source
Wavelength

1310,1490,1550,1625nm (±20nm)

Emitter Type

FP-LD@1310,1490,1550nm; DFB-LD@1625nm

Output Mode

CW, 270Hz,1KHz,2KHz

Spectrum Width

≤5nm

Output Power

≥ -3dBm

Power Stability

±0.05dB/15min; ±0.10dB/8hr

Connector

   FC/PC (Interchangeable SC, ST)

MPN200 General Loss Tester Module: Optical Power Meter
CAL Wavelength

850,1300,1310,1490,1550,1625, 1650nm

Power Range (dBm)

-70~+10 (-60~+10@850nm)

-50~+27

Accuracy

±5%±0.01nW (±0.5dB@850nm)

±5%±1nW (±0.5dB@850nm)

Detector Type

InGaAs

MOD Identification

270,1K,2K Hz

Resolution

0.01dB

Connector

FC (Interchangeable SC, ST)

Notes: (1) Burst mode measurement range at 1310 nm: -30 ~ +10dBm;

* Specifications subject to change without notice

 

Options:

1. MOT200-XXXX-P      OTDR Splitter-pass-through option

2. MOT200-XXXX-L       OTDR Live Testing – In service function (1625 or 1650nm with filter)

3. MPN100                     Built-in OPM for OTDR modules

4. MOT200-XXXX-X-S  Stabilized Laser Source function for OTDR modules (Same working  wavelength of OTDR, output power≥-7dBm)

Posted on Leave a comment

Shineway OTDR – palmOTDR

Shineway OTDR palmOTDR
Shineway OTDR palmOTDR
Shineway OTDR palmOTDR

Shineway OTDR palmOTDR Series

Most Compact High-Performance Shineway palmOTDR OTDR

Comprehensive fiber applications, ideal for LAN/WAN/FTTx certification & trouble-shooting:SM: 1310/1490/1550, 1625/1650nm (with filter), up to 45dBMM: 850/1300nm, 21/24dB.

  • Fault locating, fiber length/loss measurement, connector/ splice/ splitter/ macro bend/fiber-end detection
  • Built-in PON Power Meter for Triple-play live measurement
  • Optional Stabilized Laser Source, SM/MM Power Meter and VFL
  • FTTx in-service testing/ Testing through splitter: (1625/1650nm with filter)
  • Splitter & fiber-end identifiable
  • Auto/Manual(2-point/5-point)/Averaging/Real-time test
  • Pass/Fail assessment and ORL test function
  • Quick start: <5 seconds
  • Perfect user interface, handheld & lightweight (1kg)
  • Hotkeys: Easiest operation in the world, push-and-test
  • 1000 test records storage
  • Bellcore file format (.sor)
  • PC software for batch data processing
  • USB/RS-232 data interface, driver-free
  • Multiple languages: EN/DE/IT/FR/ES/PT/RU/KR/VN/CN etc.
  • 8 hrs continuous operation/20 hrs standby
  • Dust-shock proof (2mdrop test)
  • CE, FCC, FDA certificates

 

The compact Shineway OTDR – palmOTDR now offers even more testing capacities, flexibility and value with combination of 850/1300/1310/1490/1550/1625/1650nm (Mono/double/triple wavelength) OTDR, 1310/1490/1550nm PON Power Meter, Stabilized Laser Source and VFL. The OTDR wavelengths cover the applications of regular end-to-end fiber characterization (1310/1550nm), premise/enterprise LAN testing (850/1300nm), FTTx fiber link construction verification (1490nm) and PON live fiber troubleshooting (1625/1650nm with filter). The integrated PON Power Meter can perform in-service testing of all PON signals (1310/1490/1550nm) on any spot of the network featuring pass-through design and burst mode support. palmOTDR is your ultimate solution to meet various testing requirements of entire fiber network.

  • In-service testing (1625/1650nm with filter)
  • Testing through splitter, splitter and fiber end identifiable

Shineway OTDR – palmOTDR – Live Optical Signal Check

When Shineway OTDR palmOTDR tests with 1310/1490/1550nm wavelength, the live signals transmitting in the tested fiber may not only affect OTDR measurements but also damage the equipments connected to the network (SDH/WDM/PON) and OTDR receiver. palmOTDR series avoids the problem by starting in-service communication check before testing with message warning and auto termination functions to effectively protect test instruments and communications equipments.

Shineway OTDR – palmOTDR – Built-in PON Power Meter

The integration of PON Power Meter into such a small unit of palmOTDR makes FTTx certification and troubleshooting an exciting experience and efficient work. The PON Power Meter module can perform in-service testing of all PON signals (1310/1490/1550nm) on any spot of the network featuring pass-through design, burst mode and Pass/Warning/Fail assessment function, which can greatly help you evaluate PON signals transmission quality.

Shineway OTDR – palmOTDR – Optional Stabilized Laser Source

Stabilized Laser Source shares Shineway OTDR palmOTDR optical port and work on the same working wavelength of Shineway OTDR – palmOTDR.

Shineway OTDR – palmOTDR – Optional Optical Power Meter

  • No warm-up
  • Absolute power value and power loss measurement
  • High accuracy, zero shift
  • Power monitoring, high-low limit setting
  • Reference setting

Shineway OTDR – palmOTDR – OTDR TraceManager Software

TraceManager software can display, analyze and edit trace files, generate and print comprehensive test and analysis reports in various forms.

  • Trace viewing, events analysis
  • Multi traces comparison
  • Batch editing and flexible printing
  • Bidirectional testing (Optional)
  • CSV/ASCII report formats

 

Shineway OTDR – palmOTDR – General Specifications

Model (1)

Wavelength (±20nm)

Dynamic     Range(2)

Event DeadZone(m)(3)

Attenuation DeadZone(m)(3)

palmOTDR-M20AE

850/1300

21/24dB

1.8

8

palmOTDR-S20AE

1310/1550

28/26dB

1.8

8/10

palmOTDR-S20BE

1310/1550

34/32dB

1.8

8/10

palmOTDR-S20C/N

1310/1550

38/37dB

2.5

14

palmOTDR-S20D/N

1310/1550

45/43dB

2.5

14

palmOTDR-S20C/P

1310/1490/1550

38/37/37dB

2.5

14

palmOTDR-S20C/X

1310/1550/1625

38/37/37dB

1.5

10

palmOTDR-S20C/E

1310/1550/1650

38/37/37dB

1.5

10

palmOTDR-P11C (w. PPM module)

1625

37dB

1.5

10

palmOTDR-P13C(w. PPM module)

1650

37dB

1.5

10

palmOTDR-P31C(w. PPM module)

1310/1550/1625

38/37/37dB

1.5

10

palmOTDR-P33C(w. PPM module)

1310/1550/1650

38/37/37dB

1.5

10

Selectable Range (Km) (4)

0.1,0.3,0.5,1.3,2.5,5,10@850nm; 0.1,0.3,0.5,1.3,2.5,5,10,20,40,80@1300nm;0.3,1.3,2.5,5,10,20,40,80,120,160,240@others

Pulse Width (5)

12ns,30ns,100ns,275ns,1µs@850nm; 12ns,30ns,100ns,275ns,1µs,2.5µs@1300nm; 5ns,10ns,12ns,30ns,100ns,275ns,300ns,1µs,2.5µs,10µs,20µs@others

Averaging Time

Quick, 15s, 30s, 1min, 2min, 3min

Distance Measure Accuracy

±(1m + 5×10-5×distance + sampling space)

Attenuation Detect Accuracy

±0.05 dB/ dB

Reflection Detect Accuracy

±4 dB

Data Storage

1000 records

Connectivity

USB/RS-232

Connector

FC (Interchangeable SC, ST)

Power Supply

NiMH Battery / AC Adapter

Battery Life

8 hrs continuous operation, 20 hrs standby (on one charge); recharging time < 4 hrs

Operating Temperature

0℃ ~ 50℃

Storage Temperature

-20℃ ~ 70℃

Relative Humidity

0~95% (non-condensing)

Weight

1kg (2.2 lbs)

Dimensions (H×W×T)

220×110×70mm (8.7×4.3×2.7 inch)

 

Shineway OTDR – palmOTDR – Functional Module Specifications

Optical Power Meter Module(9)

Calibrated Wavelength (nm)

8.50E+22

Power Range (dBm)

-70 ~ +6 (-60 ~ +6 @ 850nm)

Detector Type

InGaAs

Display Resolution

0.01dB

Accuracy

± 5% ± 0.01nW(±0.5dB@850nm)

MOD Identification

1K, 2K Hz

PON Power Meter Module(10)

Calibrated Wavelength

1310nm

1490nm

1550nm

Measurement Range (dBm)

-40 ~ +8 (Burst mode: -30 ~ +8)

-40 ~ +8

-40 ~ +20

Spectral Passband (nm)

1310±40

1490±10

1550±10

Power Uncertainty (dB)

≤ 0.5

Display Resolution (dB)

0.01

Insertion Loss (dB)

≤ 1.5

Threshold

60 user-definable threshold sets

Data Storage

1200 records

Notes:

(1)  Specifications describe the instrument’s warranted performance, measured with typical PC-type connectors. Uncertainties due to the refractive index of fiber are not considered.

(2)  The dynamic range is measured at maximum pulse width within averaging time of 3 minutes.

(3)  Conditions for dead zone measurement: Reflection event is at0.6Km, reflection intensity is less than -45dB, event dead zone is measured with pulse width of 10ns (type A with 12ns); attenuation dead zone is measured with pulse width of 30ns.

(4)  Among the selectable ranges 160 and240kmare only for type B, C & D;120Kmis only for type A.

(5)  Among the pulse widths 5ns, 10ns, 300ns, 10μs and 20μs are only available for type B, C & D; 12ns and 275ns are only for type A.

(6)  Visible fault locator module is standard on S20BE, S20C/N and S20D/N; optional on M20AE, S20AE, S20C/P, S20C/X, S20C/E, P11C and P13C.

(7)  Stabilized laser source module is optional on all models.

(8)  Stabilized laser source shares palmOTDR optical port and work on the same working wavelength of palmOTDR.

(9)  Optical power meter module is optional on M20AE, S20AE, S20BE, S20C/N, S20D/N, S20C/P, S20C/X and S20C/E.

(10) PON power meter module is standard on P11C, P13C, P31C and P33C.

* Specifications subject to change without notice

 

Options:

1.      palmOTDR-XXX-V   Visible Fault Locator module for palmOTDR

2.      palmOTDR-XXX-P   Optical Power Meter module for palmOTDR

3.      palmOTDR-XXX-S   Stabilized Laser Source module for palmOTDR